Primary water quality criteria for designated-best-use-classes


back
Designated-Best-Use Class of water Criteria
Drinking water source without conventional treatment but after disinfection A
  • Total Coliforms Organism MPN/100ml shall be 50 or less
  • pH between 6.5 and 8.5
  • Dissolved oxygen 6mg/1 or more
  • Biochemical Oxygen Demand 5 days 20oC 2mg/1or less
Outdoor bathing (Organised) B
  • Total Coliforms Organism MPN/100ml shall be 500 or less
  • pH between 6.5 and 8.5
  • Dissolved Oxygen 5mg/1 or more
  • Biochemical Oxygen Demand 5 days 20oC 3mg/1 or less
Drinking water source after conventional treatment and disinfection C
  • 1.Total Coliforms Organism MPN/100ml shall be 5000 or less
  • pH between 6 to 9
  • Dissolved Oxygen 4mg/1 or more
  • Biochemical Oxygen Demand 5 days 20oC 3mg/1 or less
Propagation of Wildlife and Fisheries D
  • pH between 6.5 to 8.5
  • Dissolved Oxygen 4mg/1 or more
  • Free Ammonia (as N) 1.2mg/1 or less
Irrigation, Industrial Cooling, Controlled Waste disposal E
  • pH between 6.0 to 8.5
  • Electrical Conductivity at 25oC micro mhos/cm Max. 2250
  • Sodium absorption Ratio Max. 26
  • Boron Max. 2mg/1